23
No-OIL
Not applicable for PRO engines
24
OverCurr
The electrical current to the engine is too high.
Starter may be jammed
Kero/glow plug is short circuited
25
No Pump!
There is either no pump connected, or the pump cable is defective.
26
Wrong Pmp
Wrong pump type, see pump configuration in the advanced section of the manual.
27
Pump Err
Communication to pump driver disturbed.
28
No Fuel!
Not applicable for PRO engines
29
LoRpmPmp
Pump driver problem
30
LowRpmFB
Rpm measurement subsystem error
31
!Clutch
Clutch of Starter motor does not disengage
32
EngMatch
Not applicable for PRO engines
33
CAN-Error
Engine has been started up via CAN-Bus, but then the CAN Bus has been
disconnected (no commands received)
34
NoRcPuls
Engine has been started up via THR channel, but then the THR signal has been
disconnected.
35
RotorBlck
Rotor of engine is blocked
36
Kill Sig
The “Kill signal” was activated, which will turn off the power to the fuel solenoids as
well as disable power to the pump(s) via an independent secondary hardware
circuit. (See also: pinout of 15pin SUB-D connector)
37
Restart Aborted
AutoRestart was triggered and AutoRestart option is set to “MaxThrottle”.
However throttle stick was not set to max throttle position by user within 6sec
timeout periode
Restart aborted