M
Ingenieurbüro CAT, M. Zipperer GmbH +49-7634-5056-800
Wettelbrunner Straße 6
61
79282 Ballrechten-Dottingen
www.jetcat.de
GERMANY
Instruction manual JetCat-PRO engines, 1.7 - V12.01V
ThrustDiffOffDly
Allowed time in multiples of 0,1s where the thrust differential compared to other engine
in Newtons is allowed to be higher than the programmed window. A setting of 0 disables
the shut down due too high differential thrust, the limiter function stays active though.
Only available if “Engine CrossChk” is not set to “Disabled”
Generator-Charge
Generator function Enabled or Disabled; only on engines with generator functionality
StartUp Mode
This function allows to select different start procedures for the THR-input (PWM or
analogue signal)
You can select between following settings:
[SEQUENCE]:
Default setting: Throttle trim to maximum, throttle stick to idle, AUX switch to center
and now move the throttle stick to maximum to start the engine.
By using the Single Channel Mode (devoid of the AUX switch) start the engine by set the
throttle trim to maximum and then move the throttle stick to maximum.
THROTTLE MAX:
Throttle trim and throttle stick to maximum. Turbine starts if the AUX-switch is set to
center.
By Single Channel Mode (devoid of AUX switch) the engine starts by move the throttle
stick more than 95% of maximum.
THROTTLE MIN:
Throttle trim to maximum and throttle stick to minimum. Turbine starts if the AUX-
switch is set to center.
By Single Channel Mode (devoid of AUX switch) the engine starts by move the throttle
stick more than 95% of maximum.
IMMEDIATE:
The engine starts direct by move the throttle trim to maximum and set the AUX-switch
to center.
By Single Channel Mode only move the throttle trim to maximum for start.
Suggestions to start a multi-engine model
Two channel Mode:
Program one ECU to
THROTTLE MAX
mode but the second to
SEQUENCE
mode.
The “Throttle max engine” starts by move the throttle trim and throttle stick to
maximum and set the Aux switch to center. To start the “Sequence engine” you now
must move the throttle stick first to minimum and back to maximum.
Single channel mode:
Program one engine to
IMMEDIATE
mode, the other to
SEQUENCE
mode.
Throttle trim and throttle stick must be set to minimum. To start the “immediate engine”
just move the throttle trim to maximum. The “sequence engine” starts by move the
throttle stick to maximum.