Instruction manual JetCat-PRO engines, 1.7 - V12.01V
Control via analog signal (0-3,3V) fed into Airspeed input
The ECU allows to use the analogue input, normally used for the airspeed sensor, to be used for the throttle control
signal.
For this special mode, the engines “Operation mode” needs to be set to one of the “Industrial” modes and the
parameter “THR-Ctrl Input” needs to be set to “Airspeed Signal”. Both settings can be found in the Limits menu. If set
like this, obviously the airspeed signal is no longer available.
A suggested typical wiring of e.g. a potentiometer for engine thrust control to this input would then look like this:
10 kOhm
Potentiometer
to airspeed
sensor input
1,8 kOhm
Switch
(engine OFF
when closed)
10 kOhm
(+5V)
(GND)
+5V
ECU-internal
GND
22
0
kO
hm
analog
input (0-3,3V)
+3.3V
Potentiometer
Position
Switch Position Action
Resulting
approx.. control
voltage
Left (min) position
Closed
Engine OFF
0V
Right (max) position
Closed
Engine OFF
0V
Left (min) position
Open
Engine idle
0,41V
Right (max) position
Open
Engine full power 2,7V
Potentiometer/switch
circuitry disconnected
---
Error
Off
>3.13V treated as
error/failure
If the potentiometer circuitry should accidentally be disconnected to the analog input, the signal would internally be
pulled high (3,3V), allowing the ECU to detect this as a failure and shutting down the engine.