M
Ingenieurbüro CAT, M. Zipperer GmbH +49-7634-5056-800
Wettelbrunner Straße 6
17
79282 Ballrechten-Dottingen
www.jetcat.de
GERMANY
Instruction manual JetCat-PRO engines, 1.7 - V12.01V
Fuel connector port
Fuel
Use JetA1 premixed with 5% JetCat Turbine Oil
Pre-filter the fuel when filling the fuel tank.
Use a large size header tank in front of the engine, for additional fuel filtering and removal of air bubbles. The
use of a “normal” fuel filter in the fuel supply line is not recommended, due to possible generation of
cavitation air bubbles!
Fuel Connection Diagram, Standard
Do not use a filter in the suction line to the engine just an UAT air trap or large felt clunk!!!
On engines above 400N thrust two felt clunks in parallel might be needed not to restrict flow, or one high flow felt
clunk from JetCat.
The fuel demands are high, especially on larger engines, and require large tubing interconnecting
the tanks. Use short connections and large diameter tubing’s.
Feeder/Hoppertank
Main-tank
To filling connector
make sure to close after filling!
Large Mesh/Felt to reject air bubbles
Fuel pickup clunk
Can be large felt clunk or similar
Overflow
No additional Filter in suction line!