-34-
P0.04
Auxiliary frequency
source Y selection
Keyboard setting frequency(P0.08,
UP/DOW N editable, not retentive at
power failure)
0
0
★
Keyboard setting frequency(P0.08,
UP/DOW N editable, retentive at power
failure)
1
Analog AI1 setting
2
Analog AI2 setting
3
AI3(keyboard potentiometer)
4
High speed pulse setting(DI5)
5
Multi-speed operation setting
6
Simple PLC setting
7
PID control setting
8
Remote communication setting
9
When used as an independent frequency input channel (frequency source switched over from X to
Y), the auxiliary frequency source Y is used in the same way as the main frequency source X (refer to
P0.03).
When the auxiliary frequency source is used for operation (frequency source is "X and Y operation"),
pay attention to the following aspects:
1) If the auxiliary frequency source Y is digital setting, the preset frequency, P0.08 does not take
effect. You can directly adjust the set main frequency by pressing keysand on the operation panel (or
using the UP/DOW N function of input terminals).
2) If the auxiliary frequency source is analog input (AI1, AI2 and AI3) or pulse setting, 100% of the
input corresponds to the range of the auxiliary frequency Y (set in P0.05 and P0.06).
3) If the auxiliary frequency source is pulse setting, it is similar to analog input.
The main frequency source X and auxiliary frequency source Y must not use the same channel. That
is, P0.03 and P0.04 cannot be set to the same value.
P0.05
Auxiliary frequency Y
reference.
Relative to maximum frequency
0
0
☆
Relative to main frequency source X
1
P0.06
Range of auxiliary
frequency Y for X and Y
operation
0%~150%
100%
☆
If X and Y operation is used, P0.05 and P0.06 are used to set the adjustment range of the auxiliary
frequency source.
You can set the auxiliary frequency to be relative to either maximum frequency or main frequency X.
If relative to main frequency X, the setting range of the auxiliary frequency Y varies according to the main
frequency X.
Содержание DLB1-0D40S2G
Страница 10: ...10 Graph 1 5 5 5 7 5KW product outline dimensions Graph 1 611 18 5KW product outline dimensions...
Страница 11: ...11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions...
Страница 12: ...12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions...
Страница 14: ...14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram...
Страница 15: ...15 Graph 2 922 400KW inverter wiring diagram...
Страница 159: ...159...