10.2.5 Alarm signal
You can define the conditions which cause an alarm to be initiated here. Alarm signals indicate that an
irregularity has occurred in the sensor.
The following causes may trigger the alarm:
Invalid trigger
Trigger during image acquisition, job switching or during parameter
setting via the process interface ("SP"-Datagram)
Evaluation cancelled
prematurely
The result of computing was not present at the latest output time.
Error in job selection
Invalid job number or job could not be loaded, e.g. because it is not
correctly configured.
Error at process interface
An error occurred during data transfer to the process interface, e.g. an
invalid command is received.
FTP client could not send all
files
An error occurred while transferring the images via the FTP client.
Possible causes could include: Device or server overloaded, incorrect
access details or server cannot be reached.