Technical Documentation
opti-check
v2.8.2-K11
182/332
ipf electronic GmbH
Lüdenscheid, Germany
Control buttons
You can move the CIELab coordinate system freely with the mouse and zoom with mouse wheel. There are
also buttons to stop the animation and tilt the CIELab colour coordinate system.
If the feature check is to be corrected by the result of the part location, you can choose this option
here.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P" (Pass); "F"
(Fail)
Reference area brightness
Integer
Field of view, colour, area
Integer list
Three values are listed for each combination
of a field of view and a colour (field of view,
colour, area).
Field of view:
Number, starting with 1 (not
as letters)
Colour:
Number, starting with 1
Area:
Proportion (in percent) of the field of
view occupied by the colour
Dominant colour
Integer list
Number of the dominant colour for each field
of view, or 0 if no colour is found
Pass/Fail
Text
Results for the individual fields of view as
"P" (Pass) or "F" (Fail)
Содержание opti-check