Technical Documentation
opti-check
v2.8.2-K11
237/332
ipf electronic GmbH
Lüdenscheid, Germany
13.7 Alarm signal
The alarm signal is activated under the following conditions in
parallel with the Pass/Fail signal
of the
current image acquisition/analysis operation
:
Invalid trigger (trigger during image acquisition or job switching)
Analysis aborted prematurely (output time exceeded)
Error in job selection (invalid job number)
Error at process interface
FTP Alarm (An error occurred while transferring the images via the FTP client.)
If image analysis is not being performed at this time, the alarm signal is activated in parallel with the
Pass/Fail signal of the
next image acquisition/analysis operation
if an error occurs.
NOTE
This output time for the alarm signal is not necessarily the next (seen chronologically)
Pass/Fail signal if you are using the
Camera Ready
or
Result valid
signals.
The alarm signal is activated immediately under the following circumstances and maintained
until the next
trigger or until a successful job switch
:
Job switching
o
if a job is selected that is not completely configured
o
if a job is selected that is not present
Device activation
o
if an active job was not selected at Power On
Содержание opti-check
Страница 1: ...Technical Documentation opti check...