Technical Documentation
opti-check
v2.8.2-K11
280/332
ipf electronic GmbH
Lüdenscheid, Germany
When a job is being transferred via the process interface, the current status of this action can be queried by
the PLC. The corresponding bit "Job update active" is set during the data transfer period. This bit remains set
until the job has been completely transferred and stored or an error has occurred. The success of the action
can then be assessed by the corresponding bits "Job-update
– OK" and "Job update – error". These flags
are retained until the next transfer of a job.
If the sensor is in
Activated
mode, the current job number is entered in the datagram.
0000
is entered here
in all other operating modes.
Here are two examples of possible states of the device:
Character string
Meaning
0 0 8 5 0 0 1 A
0
0
8
5
0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 1
Current inspection mode:
Activated
Acquisition: External trigger
Protocol: Polling mode
Active job: 26 (Hex: 1A)
0 0 2 9 0 0 0 0
0
0
2
9
0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 1
Current inspection mode:
Configuration
Acquisition: Continuous
Protocol: Polling mode
Active job: -
Содержание opti-check
Страница 1: ...Technical Documentation opti check...