![background image](http://html1.mh-extra.com/html/ipf-electronic/opti-check/opti-check_technical-documentation-manual_2088919157.webp)
Technical Documentation
opti-check
v2.8.2-K11
157/332
ipf electronic GmbH
Lüdenscheid, Germany
Determine the direction of the contour points that should be taken into consideration (device
dependant).
If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P" (Pass); "F" (Fail)
Number of contour points
Integer
Содержание opti-check
Страница 1: ...Technical Documentation opti check...