Technical Documentation
opti-check
v2.8.2-K11
312/332
ipf electronic GmbH
Lüdenscheid, Germany
15.5.3.5 Depiction of the data elements on the PROFINET module
The following tables provide a brief overview of the arrangement of data elements in the individual modules.
15.5.3.5.1
Module: Control and status
Input data (device
PLC)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
output data
pad (0)
C -> D
HS
ACK
pad (0)
C -> D
HSWA
ACT
ACK
C -> D
HSS
ACT
ACK
1
Handshake for
input data
pad (0)
D -> C
HS
Flag
pad (0)
D -> C
HSWA
ACT
ACK
D -> C
HSS
ACT
ACK
2
Device status
pad (0)
Img Proc
ACT
Operating Mode
Teach
ACT
TRG
RDY
3
Current job number
Active job number
4
pad (0)
5
Action status
pad (0)
Status SM
Status SP
Status SJ
6
Job results
pad (0)
Sub
Res 5
Fail
Sub
Res 5
Pass
7
Sub Res
4 Fail
Sub Res
4 Pass
Sub Res
3 Fail
Sub Res
3 Pass
Sub Res
2 Fail
Sub Res
2 Pass
Sub
Res 1
Fail
Sub
Res 1
Pass
8
pad (0)
9
pad (0)
Alarm
Total
Res Fail
Total
Res
Pass
10
Device alarms
pad (0)
11
pad (0)
12
Alarm
PIF
HS Err
13
Alarm
PIF
Pipe OV
Alarm
PIF
Buf OV
Alarm
FTP
Alarm
PIF
Alarm
Inv Job
Alarm
Output
Timeout
Alarm
Inv TRG
Alarm
(Any)
Output data (PLC
device)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
output data
pad (0)
C -> D
HS
Flag
pad (0)
C -> D
HSWA
ACT
C -> D
HSS
ACT
1
Handshake for
input data
pad (0)
D -> C
HS
ACK
pad (0)
D -> C
HSWA
ACT
D -> C
HSS
ACT
2
Device controller
pad (0)
Operating
mode
Teach
TRG
3
Job selection
Select job number
4
Reset statistics
Reset statistics
5
Reset status
(actions)
pad (0)
Reset
State SM
pad (0)
Reset
State SP
pad
(0)
Reset
State
SJ
Содержание opti-check