NOTE
Characters allowed in file names and job names:
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ÀÁÂÃÄÅÈÉÊËÌÍÎÏ
àáâãäåèéêëìíîï
ÐÑÒÓÔÕÖÙÚÛÜÝß
ðñòóôõöùúûüýÿÇ,
¦!#$%&'+-÷×±,.
¡@_`()[]{}«»~
ATTENTION!
Connection, installation and initial set-up may only be carried out by specialized
personnel.
Protect optical areas from moisture and dirt.
ATTENTION!
The IP protection class is only valid if
all
connectors are connected as described in the
technical documentation and, for devices with protection class IP 69K, if the sealing screw
on the lens setting opening is correctly screwed in.
ATTENTION!
Disconnection of power to the unit during booting can result in damaged files.
Never disconnect the power supply during booting. Booting is finished when intermittent
blinking of the PASS / FAIL
– LED or blinking of the POWER LED has stopped.
ATTENTION!
The device may become warm during operation. High temperatures may damage the
device. Ensure that any heat generated is dispersed by installing it with the rear to a good
heat conductor (metal). The housing temperature must not exceed 50°C.
Direct mounting on a solid metal object without using a retaining bracket is required when
operated in the limit zone (e.g. full load on the flash controller and utilisation of the
maximum operating temperature)!
For devices with integrated Industrial Ethernet only:
These devices are equipped with an internal temperature monitor for built-in protection.
There may be a warning message or emergency shutdown if the device is operated
outside its specified range.