Technical Documentation
opti-check
v2.8.2-K11
226/332
ipf electronic GmbH
Lüdenscheid, Germany
12.4.7 Appendix: Quality characteristics for barcodes and matrix codes
Numerous quality characteristics are defined for the various code types, these characteristics are described
in more detail in the following. Keep in mind that illumination arrangements and quality requirements are
defined on the image for these standards so that the values determined cannot be directly mapped to your
installation situation!
Barcode quality characteristics (ISO/IEC 15416)
Designation
Description
Legibility
A = Code legible
F = Code not read
Symbol contrast
Difference between the maximum and minimum grey scale value of
the symbols
Minimum reflection
A = Minimum grey scale value ≤ 0.5 * maximum grey scale value
F = Other
Edge contrast
Minimum contrast between two symbol elements
Modulation
Amplitude between symbol elements
Defects
Irregularities in the grey scale profile of a symbol
Decodability
Deviations in the width of symbol elements
Additional code-specific
parameters
Depending on code type, for example, evaluation of the width of the
quiet zones or ratio of symbol widths.
Quality characteristics DataMatrix (ECC200) and QR code (ISO/IEC 15415 + AIM DPM-1-2006)
Designation
Example
Description
Contrast
Difference between the maximum and minimum
grey scale value of the modules
Modulation
Amplitude between data code modules
(dependant on error correction!)
Pattern damage
Disturbances in the frame pattern (finder
pattern)
Legibility
A = Code legible
F = Code not read
Содержание opti-check
Страница 1: ...Technical Documentation opti check...