Technical Documentation
opti-check
v2.8.2-K11
60/332
ipf electronic GmbH
Lüdenscheid, Germany
NOTE
If the set output time has been reached prematurely, the calculation in the Vision Sensor
is aborted. The result and all partial results are then NOK.
The duration of the output signal is used to specify for how long the output signal (Result
valid, Pass/Fail, Alarm) should be produced. Depending on the settings, the signal will
either be reset once the set pulse has elapsed, or reset with the next result.
NOTE
If you have connected an encoder, you may set output time and duration as a distance.
In addition, you can specify an "output run-up" in milliseconds to activate the Pass/Fail
signal before reaching a specific position.
This option is available if an exact output time has been specified (identical earliest and
latest output times) and this is specified as a distance.
Keep in mind that, in this case, the conveyor speed must be constant!
There is also the option to set different times for individual outputs.
In the drop-down menu, different individual timings can now be set for outputs with a result. These are
selected with the checkbox.
In this example, only output 3 has a different output time, although output 2 is also in use. They both follow
the general output time.
Содержание opti-check
Страница 1: ...Technical Documentation opti check...