Technical Documentation
opti-check
v2.8.2-K11
298/332
ipf electronic GmbH
Lüdenscheid, Germany
15.5.2.2 Group: Control and status
This group gives you access to Control (e.g. trigger, teach), Job number (switching between jobs), State (e.g.
status of the job changeover) and Job result (results of the feature checks) and alarms.
Data element
Direction
Type
Length
(byte)
Description
Device
controller
PLC
device
UINT8
1
Control word
Bit 0
Trigger (switching from 0 -> 1 triggers
image acquisition), corresponds with
the "TR" process interface command
Bit 1
Teach (if 1 is triggered during image
acquisition, Teach is carried out),
corresponds with the "TE" process
interface command
Bit 2
Operating mode (switching from 0 ->
1 switches to set-up mode, switching
from 1 -> 0 switches to run mode),
corresponds with the "SM" process
interface command
Bits 3..7
Reserved (always 0)
Job selection
PLC
device
UINT8
1
Current job number (changing triggers job switching,
job number eff. 0x01..0xFF, 0x00 -> does not trigger
job switching ("Inactive"), corresponds with the "SJ"
process interface command
Reset statistics
PLC
device
UINT8
1
Reset statistics (changing triggers a statistics reset
for the corresponding job number, eff. 0x01..0xFF,
0x00 -> does not trigger a statistics reset
("Inactive"), corresponds with the "CS" process
interface command
Reset status
(actions)
PLC
device
UINT8
1
Resets the status for various actions
Bit 0
Reset job switching status (changing
from 0 -> 1 triggers a reset if the
status is not "in progress")
Bit 1
Reserved (always 0)
Bit 2
Reset SetParam status (changing
from 0 -> 1 triggers a reset if the
status is not "in progress")
Bit 3
Reserved (always 0)
Bit 4
Reset mode switching status
(changing from 0 -> 1 triggers a reset
if the status is not "in progress")
Bit 5..7
Reserved (always 0)
Содержание opti-check