Technical Documentation
opti-check
v2.8.2-K11
185/332
ipf electronic GmbH
Lüdenscheid, Germany
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P"
(Pass); "F" (Fail)
Number of objects
Integer
Reference area brightness
Integer
List of centres
Float-Point list
List of areas
Float-Point list
List of structure values
Integer list
Number of contour points within
the respective area (BLOB).
List of lightness values
Integer list
Average grey value within the
respective area.