Cleaning and Maintenance
User Manual H12 / SCAMAX® 8x1 - Version 2019.12
7.2.3.
Cleaning the Separation Roller Friction Linings
A rising level of Double Feed Inputs (
see chapter
is often a sign that the Separation Roller Friction Linings
should be cleaned. To do this, open the Scan Plane of the
device (
see chapter
) as much as necessary and press
with a pen or the like on the lock of the Cover Separation
Roller to fold it open. Now the Separation Roller can be
removed easily from its holder.
To clean, a lint-free cloth is soaked with some SCAMAX®
SV1A Cleaning Solution for Rubbers & Belts and thus
rubbed over each lining of the Separation Roller until
the adherent dirt is removed and the lining has a good
grip again. Then let the Separation Roller to dry for at
least 10 minutes
For installation, slide the Separation Roller with the
lateral guides back to the holder, close the Cover
Separation Roller and lock it up with light pressure.
7.2.4.
Replacing the Separation Roller Friction Linings
For the exchange, the Separation Roller must be removed beforehand as described in the previous
chapter. Since there is a much harder material used for the linings of the Separation Roller as for
the Feeder Roller Friction Linings
(see chapter
),
It is necessary to press the linings with your thumb
around, outwards over the bead of the plastic carrier
before they can be pulled sideways. When sliding
the new linings (
see chapter
) it must be ensured
that they are completely on the roller in the guides.
The installation of the Separation Roller is carried out
again as described in the previous chapter.
7.3.
Cleaning/Maintenance of the Scan Plane
Since paper and ink get deposited in the device during scanning, but partly also small paper parts and
other residues, it makes sense that the Scan Plane and some specific areas are cleaned periodically.
The frequency per area is dependent on the kind of documents to be processed. To do this, use only
the supplied cleaning devices or vacuum cleaner meant for this.
Never use compressed air! You
should also refer to the note in chapter
For cleaning activities in the Scan Plane, it should always be completely open (
section
). To clean the
area, wiping the surfaces with the supplied Swiffer® Dusters™ Cleaner Kit or a soft cloth is sufficient.
If adherent residues are on the sheet metal parts within the scan plane (
e.g. adhesive
), this may be
removed with the SCAMAX® SV1A Cleaning Solution for Rubbers & Belts.