Opening the Scanner
User Manual H12 / SCAMAX® 8x1 - Version 2019.12
6.5.
Removing/Attaching the Base Cover
The Base Cover on the rear panel must be removed to
gain access to the Rear Output (
next chapter
). For this,
pull the cover on the top of the adjacent magnetic hol-
ders and lift out the bottom attached suspensions. To
attach the Base Cover, attach the suspensions back to
the appropriate pins and fold the cover upwards against
the magnetic holders.
6.6.
Removing/Inserting the Rear Output Pressure Unit
The Rear Output Pressure Unit is covered by the Base
Cover. These must be removed first (
previous chapter
),
the Pressure Unit is to be taken out in case of a fault or
for cleaning.
The Rear Output Pressure Unit is fixed laterally with two
locks. To unlock, these must be pulled out. If they are
thereby slightly turned, they remain in the unlocked
position. Additionally the grounding cable which is
mounted on the right hand side has to be unplugged.
Now, the Pressure Unit can be pulled out at the rear in
order to remove any jammed outputs or scraps of paper,
staples or the like stuck in this area. To install, pull out
the two locks again, push back the pressure unit to the
designated place, allow the locks to slide back again
into the guides and plug on the grounding cable again..