ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
LED, buzzer, visualisation
Manage visualisation
393
Parameters of the inputs
3382
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
X INT
input
value
XH
INT
upper limit of the value range
XL
INT
lower limit of the value range
MODE
BYTE
operating mode of the rows of LEDs,
value range = 0...10
CHANGEPOINT
BYTE
colour change point for MODE = 9 or 10,
value range = 0...10
Operating mode of the row of LEDs
3383
All variables of this program are stored in the global variables of the library.
Mode
Row of LEDs
Description
1
Red individual segment in a row of LEDs lighting green
2
Green individual segment in a row of LEDs lighting red
3
Red individual segment
4
Green individual segment
5
Red row of segments in a row of LEDs lighting green
6
Green row of segments in a row of LEDs lighting red
7
Red row of segments
8
Green row of segments
9
Red row of segments with colour change point (here
CHANGEPOINT = 5)
10
Green row of segments with colour change point (here
CHANGEPOINT = 7)