ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
234
J1939_RX
7724
Unit type = function block (FB)
Contained in the library:
ifm_J1939_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7725
J1939_RX is the easiest method for receiving single frame messages. The message read last on the
CAN bus is returned.
Parameters of the inputs
7726
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
CHANNEL
BYTE
CAN interface (1...n) depending on the device
PGN DWORD
PGN
=
P
arameter
G
roup
N
umber
permissible values = 0000 0000...0003 FFFF
16
(0...262 143
10
)
NOTE:
The PGN = 0 is not used.