ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
241
Parameters of the outputs
7763
Parameter
Data type
Description
REDSTOPLAMP
BOOL
red stop lamp
TRUE: OFF
FALSE: ON
AMBERWARNINGLAMP
BOOL
Amber warning lamp
TRUE: OUT
FALSE: ON
PROTECTLAMP BOOL
protect
lamp
TRUE: OFF
FALSE: ON
NUMBER
BYTE
number of the bytes received (0...8)
SPN WORD
S
uspect
P
arameter
N
umber
FMI BYTE
F
ailure
M
ode
I
ndicator
permissible values = 00...1F
16
= 0...31
10
SPN_CM BOOL
conversion
method
preset = FALSE
OC BYTE
occurrence
count
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
FB execution completed without error – data is valid
008
08
FB is active – no data was received
242
F2
Error: setting is not possible