TROUBLES - CAUSES - CURES
8.1. GENERAL FAULTS
8.2. BAR MAGAZINE - Faults
TROUBLE
CAUSES
CURES
The bar feeder will not start.
No power.
Check the electric connections.
Open guard.
Close the guard.
Actuated emergency devices.
Disconnect the emergency devic-
es.
Motor thermal switch tripped
Reset the motor overload cut-out
with the special push-buttons.
The bar feeder has been reset
but the automatic cycle will not
start.
No lathe signal.
Check electric connection to the
lathe.
The pneumatic devices will not
respond to controls.
No air.
Check the air system.
The pre-feed and feed suddenly
stop.
Motor thermal switch tripped.
Reset the motor overload cut-out
with the special push-buttons.
TROUBLES
CAUSES
CURES
The bar will not enter the maga-
zine during feeding.
The bar plates are too low.
Adjust the plates position.
The first magazine bar is not
dropped into the guides.
Wrong adjustment of the bar
selectors.
Adjust the bar selectors.
All the magazine bars are
dropped into the guides.
Wrong adjustment of the bar
selectors.
Adjust the bar selectors.