54
3
OPERATION INFORMATION
302.035
ERROR
CAUSE
CURE
During the bar-pusher stroke back-
wards, in the “BAR CHANGE-
OVER” phase, the encoder will
detect the “BAR FEEDER ZERO
SETTING” position but the BAR
FEEDER ZERO SETTING sensor
has not detected the bar-pusher.
The sensor is out of position.
Adjust the sensor position.
Failure of the sensor (
S7
).
Replace it.
ERROR
CAUSE
CURE
Remnant extraction or upper guide
lifting or bar selection move-
ments(controlled by motor
M3
) are
not smooth.
Movements are hindered by an
obstacle.
Remove the obstacle
Movement detecting sensors (
S1
,
S2
,
S8
) malfunction.
Check and/or replace the sensors
ERROR
CAUSE
CURE
The open collet signal exceeded the
max. time previously entered into
parameter 21
.
During the working phase
Parameter 21
value is less than the
real lathe collet opening.
Check the real “COLLET OPE-
NING” time and enter one more
second into
parameter 21
.
INFORMATION:
should parameter 21 value be zero,
its function is overridden.
During the bar change-over phase
The bar reached point
C
but the
“CLOSED COLLET” signal from
lathe fails to arrive within the pre-
scribed time.
Check the “CYCLE START” signal
from bar feeder.
Check the “CLOSED COLLET”
signal from lathe.
215
E r r o r :
c a r r i a g e
m o t o r
t i m e o u t
( 2 1 5 )
216
E r r o r :
M 3
t i m e o u t
( 2 1 6 )
217
E r r o r :
o p e n c o l l e t
t i m e o u t
( 2 1 7 )
Содержание BOSS 542 CNC
Страница 102: ...100 9 302 034 ...
Страница 107: ...2 302 035 ...
Страница 165: ...60 3 OPERATION INFORMATION 302 035 ...