89
7
BAR FEEDER MAINTENANCE
302.034
❑
❑
❑
❑
MINI BOSS and BOSS
After the brush inspection and - if need be - replacement, the partial hour counter has to
be reset, so that once the following 1250 hours are over, the message previously men-
tioned appears again.
For resetting, refer to “Control Panel Instruction Manual”, paragraph “CN functions protect-
ed by access code - Description and use”.
7.2.9 Air filter unit - Check
❑
❑
❑
❑
Filter A
•
Make sure that cup
B
is not full of condensate. If need
be, bleed the condensate by valve
C
.
❑
❑
❑
❑
Lubricator D
•
Check that the oil level is not under the suction level.
•
If need be, top up as follows:
- disconnect the compressed air supply.
- fill the tank removing plug
E
or cup
F
; the oil level
must reach the
MAX.
reference.
9÷11 Cst at 40
°
C ISO VG 10.
See paragraph 2.6. for the comparative table.
- Reset the compressed air supply.
•
Check air lubrication (1-12 drops every 1000 l. of air),
adjust by turning the screw
G
.
34.155 Ec. 1
MAX
F
G
E
D
B
C
A