57
3
OPERATION INFORMATION
302.035
ERROR
CAUSE
CURE
The bar working cycle has lasted
longer than the time entered into
parameter 22
.
The bar working cycle has lasted
longer than the time entered into
parameter 22
.
Check the real time of the cycle and
enter at least 1 more second.
The bar working cycle has been
interrupted or slowed down.
Check the bar machining.
INFORMATION: should parameter 22 value
be zero, its function is overridden.
ERROR
CAUSE
CURE
Lathe failed to thread the workpiece
to be machined.
Failure of the threading device.
Check the device.
Failure of the threading control
device.
Check the device.
ERROR
CAUSE
CURE
Bar feeders with
parameter 65
into
3 - (active continuos open contact)
or 5 - (active closed continuous con-
tact) mode only. The “START” signal
from lathe fails to be continuous.
Failure of lathe interfacing.
Check lathe interfacing and condi-
tion.
Faulty board.
Check and/or replace the board.
ERROR
CAUSE
CURE
During the machining phase, the
guides are not fully closed (the sen-
sor
S2
is not energized).
Faulty sensor (
S2
) which detects
guide closure.
Check and/or replace the sensor.
The guides have been (possibly just
partially) opened using the crank.
CAUTION: never open the guides
when machining is in progress.
Close the guides.
223
E r r o r :
w o r k p i e c e t i m e o u t
( 2 2 3 )
224
E r r o r :
t h r e a d s a f e t y
( 2 2 4 )
225
( 2 2 5 )
E r r o r :
s t a r t
f r o m
l a t h e
s i g n a l
d i s a b l e d
226
E r r o r :
o p e n g u i d e s
( 2 2 6 )
Содержание BOSS 542 CNC
Страница 102: ...100 9 302 034 ...
Страница 107: ...2 302 035 ...
Страница 165: ...60 3 OPERATION INFORMATION 302 035 ...
Страница 167: ...62 302 035 3 ...