OPERATION INFORMATION
302.035
ERROR
CAUSE
CURE
The bar feeder stopped or fails to
start.
One of the lathe doors enabling the
signal is open.
Check the door closing.
The “CLOSED DOOR” signal fails to
reach the bar feeder board.
Make sure wire 453 of terminal
board X4 is powered (24V D/C).
ERROR
CAUSE
CURE
The bar feeder stopped or fails to
start
An emergency push-button has
been pressed.
Release the push-button.
The stop push-button
has
been pressed
Press the
start push-button.
There is an emergency signal from
lathe.
Restore the lathe start and make
sure wire 426 of terminal board X2
and wire 459 of terminal board X4
are powered.
The thermal switch (
Q2
) of motor
(
M3
) controlling guide opening and
insertion/extraction has tripped.
Motor overheating.
Check motor rated current.
Check current range at phase wires.
The thermal switch (
Q1
) of motor
(
M2
) controlling the lubricating sys-
tem has tripped.
Check thermal switch setting.
If motor absorption is higher than the
rated value (see the data plate), check
the motor-controlled mechanics.
ERROR
CAUSE
CURE
Relay
K29
(spindle impulses) has
been activated for more than three
minutes.
The impulse number entered into
parameter 13
is too high.
Reduce
parameter 13
value.
Parameter 51
value
is too high.
To access this parameter, enter the
reserved code; apply to IEMCA
service department.
218
E r r o r :
d o o r
s a f e t y
( 2 1 8 )
219
E r r o r :
e m e r g e n c y ( 2 1 9 )
220
E r r o r :
s p i n d l e t i m e o u t
( 2 2 0 )