This soft copy for use by IBM employees only.
Notice that in the SP Switch, the
Estart_sw calculates the timeout based on the
number of switches:
LIMIT = 180 + ((NUM_SWITCH - 2) * 60)
where NUM_SWITCH > 2
The following steps are referred to as
Switch Initialization:
1. An
Estart is issued for a system partition from the Control Workstation,
through either SMIT or the command line, and this is relayed to the primary
node of the partition as an
Estart_sw.
2. The primary node consults the SDR for the current topology file and the
current fenced nodes.
3. The primary node distributes the topology file as appropriate:
•
The primary node distributes the topology file to the bootserver nodes of
its partition.
•
The primary node directs each bootserver to distribute the topology file
to its client nodes.
•
Each bootserver distributes the topology file, tests for success, and
returns resulting status to the primary.
•
The primary node logs and evaluates failure data.
4. The primary runs the Worm code to verify the partition
′
s fabric pool and
nodes:
•
Each chip is sent a
Read Status service package to check cabling.
•
Each chip is sent an
Initialization service package to set the chip ID and
specify routes to the primary.
•
Each non-primary unfenced node is sent an
Initialization service package
to set its personality and specify the topology file for this partition.
•
Each non-primary unfenced node is sent a
Read Status node service
package to verify the switch address, personality, and readiness.
•
The primary node updates its device database in accordance with the
findings.
5. The primary node sets the Time-of-Day (TOD) across the fabric pool:
•
Traffic is quiesced, if necessary.
•
The TOD is propagated.
•
Traffic is resumed, if necessary.
6. The primary node downloads its route table to its TB3 adapter
7. The primary node distributes device database deltas to the nodes over the
switch through the
Device Database service package
8. On each non-primary, unfenced node:
•
The local device database is updated with the deltas.
•
Routes are computed.
•
The routes are loaded to TB3 SRAM.
9. On each node, the communications protocols and Load Leveler code, as
appropriate, are notified that the switch is available.
Chapter 4. The Switch
109
Содержание RS/6000 SP
Страница 2: ......
Страница 14: ...This soft copy for use by IBM employees only xii SP PD Guide...
Страница 16: ...This soft copy for use by IBM employees only xiv SP PD Guide...
Страница 106: ...This soft copy for use by IBM employees only 86 SP PD Guide...
Страница 178: ...This soft copy for use by IBM employees only 158 SP PD Guide...
Страница 214: ...This soft copy for use by IBM employees only 194 SP PD Guide...
Страница 248: ...This soft copy for use by IBM employees only 228 SP PD Guide...
Страница 250: ...This soft copy for use by IBM employees only Figure 102 setup_authent Script Flow Chart 2 7 230 SP PD Guide...
Страница 252: ...This soft copy for use by IBM employees only Figure 104 setup_authent Script Flow Chart 4 7 232 SP PD Guide...
Страница 254: ...This soft copy for use by IBM employees only Figure 106 setup_authent Script Flow Chart 6 7 234 SP PD Guide...
Страница 258: ...This soft copy for use by IBM employees only Figure 110 install_cw Script Flow Chart 3 3 238 SP PD Guide...
Страница 260: ...This soft copy for use by IBM employees only Figure 112 setup_server Script Flow Chart 2 23 240 SP PD Guide...
Страница 262: ...This soft copy for use by IBM employees only Figure 114 setup_server Script Flow Chart 4 23 242 SP PD Guide...
Страница 264: ...This soft copy for use by IBM employees only Figure 116 setup_server Script Flow Chart 6 23 244 SP PD Guide...
Страница 266: ...This soft copy for use by IBM employees only Figure 118 setup_server Script Flow Chart 8 23 246 SP PD Guide...
Страница 268: ...This soft copy for use by IBM employees only Figure 120 setup_server Script Flow Chart 10 23 248 SP PD Guide...
Страница 270: ...This soft copy for use by IBM employees only Figure 122 setup_server Script Flow Chart 12 23 250 SP PD Guide...
Страница 272: ...This soft copy for use by IBM employees only Figure 124 setup_server Script Flow Chart 14 23 252 SP PD Guide...
Страница 274: ...This soft copy for use by IBM employees only Figure 126 setup_server Script Flow Chart 16 23 254 SP PD Guide...
Страница 276: ...This soft copy for use by IBM employees only Figure 128 setup_server Script Flow Chart 18 23 256 SP PD Guide...
Страница 278: ...This soft copy for use by IBM employees only Figure 130 setup_server Script Flow Chart 20 23 258 SP PD Guide...
Страница 280: ...This soft copy for use by IBM employees only Figure 132 setup_server Script Flow Chart 22 23 260 SP PD Guide...
Страница 284: ...This soft copy for use by IBM employees only Figure 136 rc switch Script Flow Chart 3 8 264 SP PD Guide...
Страница 286: ...This soft copy for use by IBM employees only Figure 138 rc switch Script Flow Chart 5 8 266 SP PD Guide...
Страница 288: ...This soft copy for use by IBM employees only Figure 140 rc switch Script Flow Chart 7 8 268 SP PD Guide...
Страница 290: ...This soft copy for use by IBM employees only 270 SP PD Guide...
Страница 292: ...This soft copy for use by IBM employees only 272 SP PD Guide...
Страница 300: ...This soft copy for use by IBM employees only 280 SP PD Guide...
Страница 304: ...This soft copy for use by IBM employees only 284 SP PD Guide...
Страница 308: ...This soft copy for use by IBM employees only 288 SP PD Guide...
Страница 310: ...This soft copy for use by IBM employees only 290 SP PD Guide...
Страница 316: ...IBML This soft copy for use by IBM employees only Printed in U S A SG24 4778 00...