Following is an insert from the switch topology file for this configuration that
shows how the nodes are connected to the High Performance Switch:
# Node connections in frame L01 to switch 1 in L01
s 15 3 tb0 0 0
L01-S00-BH-J18 to L01-N1
s 15 2 tb0 1 0
L01-S00-BH-J16 to L01-N3
s 16 0 tb0 2 0
L01-S00-BH-J20 to L01-N5
s 16 1 tb0 3 0
L01-S00-BH-J22 to L01-N7
s 15 1 tb0 4 0
L01-S00-BH-J14 to L01-N9
s 15 0 tb0 5 0
L01-S00-BH-J12 to L01-N11
s 16 2 tb0 6 0
L01-S00-BH-J24 to L01-N13
s 16 3 tb0 7 0
L01-S00-BH-J26 to L01-N15
s 14 3 tb0 8 0
L01-S00-BH-J10 to L01-N17
s 14 2 tb0 9 0
L01-S00-BH-J8 to L01-N19
s 17 0 tb0 10 0
L01-S00-BH-J28 to L01-N21
s 17 1 tb0 11 0
L01-S00-BH-J30 to L01-N23
s 14 1 tb0 12 0
L01-S00-BH-J6 to L01-N25
s 14 0 tb0 13 0
L01-S00-BH-J4 to L01-N27
s 17 2 tb0 14 0
L01-S00-BH-J32 to L01-N29
s 17 3 tb0 15 0
L01-S00-BH-J34 to L01-N31
Figure 58. Topology File Insert f r o m a Single Switch 16 Wide Node System
Note that the node numbering does not follow the usual convention. For
example, where you would normally expect to see “L01-N2,” there is “L01-N3.”
The node numbering in relation to the slot numbers remains consistent, but the
physical cabling has changed to enable the connection of 16 wide nodes to the
same switch board. The J16 cable now goes to slot 3 (node 3) instead of slot 2
(node 2). This pattern continues up through the 2 frames.
This has an effect on how the nodes are allocated in the various layouts. Using
the 4_12 example again, here is one of the possible configurations:
4 partition
Nodes 1, 3, 9, and 11
12 partition
Nodes 5, 7, 13, 15, 17, 19, 21, 23, 25, 27, 29, and 31
Using the topology files in this way is the only accurate method that can be used
to assess the impact of System Partitioning on all possible RS/6000 SP
configurations. However, using the
slot number method is perfectly valid for
configurations where a single switch services nodes in a single frame only.
If there was no High Performance Switch in this example of a 2 frame, 16 wide
node system, then the partitioning is done with the expectation that there would
be a High Performance Switch in each of the 2 frames, and so you would use the
slot number method to assess the impact of the various layouts on your
configuration.
Chapter 5. System Partitioning
129
Содержание RS/6000 SP
Страница 2: ......
Страница 14: ...This soft copy for use by IBM employees only xii SP PD Guide...
Страница 16: ...This soft copy for use by IBM employees only xiv SP PD Guide...
Страница 106: ...This soft copy for use by IBM employees only 86 SP PD Guide...
Страница 178: ...This soft copy for use by IBM employees only 158 SP PD Guide...
Страница 214: ...This soft copy for use by IBM employees only 194 SP PD Guide...
Страница 248: ...This soft copy for use by IBM employees only 228 SP PD Guide...
Страница 250: ...This soft copy for use by IBM employees only Figure 102 setup_authent Script Flow Chart 2 7 230 SP PD Guide...
Страница 252: ...This soft copy for use by IBM employees only Figure 104 setup_authent Script Flow Chart 4 7 232 SP PD Guide...
Страница 254: ...This soft copy for use by IBM employees only Figure 106 setup_authent Script Flow Chart 6 7 234 SP PD Guide...
Страница 258: ...This soft copy for use by IBM employees only Figure 110 install_cw Script Flow Chart 3 3 238 SP PD Guide...
Страница 260: ...This soft copy for use by IBM employees only Figure 112 setup_server Script Flow Chart 2 23 240 SP PD Guide...
Страница 262: ...This soft copy for use by IBM employees only Figure 114 setup_server Script Flow Chart 4 23 242 SP PD Guide...
Страница 264: ...This soft copy for use by IBM employees only Figure 116 setup_server Script Flow Chart 6 23 244 SP PD Guide...
Страница 266: ...This soft copy for use by IBM employees only Figure 118 setup_server Script Flow Chart 8 23 246 SP PD Guide...
Страница 268: ...This soft copy for use by IBM employees only Figure 120 setup_server Script Flow Chart 10 23 248 SP PD Guide...
Страница 270: ...This soft copy for use by IBM employees only Figure 122 setup_server Script Flow Chart 12 23 250 SP PD Guide...
Страница 272: ...This soft copy for use by IBM employees only Figure 124 setup_server Script Flow Chart 14 23 252 SP PD Guide...
Страница 274: ...This soft copy for use by IBM employees only Figure 126 setup_server Script Flow Chart 16 23 254 SP PD Guide...
Страница 276: ...This soft copy for use by IBM employees only Figure 128 setup_server Script Flow Chart 18 23 256 SP PD Guide...
Страница 278: ...This soft copy for use by IBM employees only Figure 130 setup_server Script Flow Chart 20 23 258 SP PD Guide...
Страница 280: ...This soft copy for use by IBM employees only Figure 132 setup_server Script Flow Chart 22 23 260 SP PD Guide...
Страница 284: ...This soft copy for use by IBM employees only Figure 136 rc switch Script Flow Chart 3 8 264 SP PD Guide...
Страница 286: ...This soft copy for use by IBM employees only Figure 138 rc switch Script Flow Chart 5 8 266 SP PD Guide...
Страница 288: ...This soft copy for use by IBM employees only Figure 140 rc switch Script Flow Chart 7 8 268 SP PD Guide...
Страница 290: ...This soft copy for use by IBM employees only 270 SP PD Guide...
Страница 292: ...This soft copy for use by IBM employees only 272 SP PD Guide...
Страница 300: ...This soft copy for use by IBM employees only 280 SP PD Guide...
Страница 304: ...This soft copy for use by IBM employees only 284 SP PD Guide...
Страница 308: ...This soft copy for use by IBM employees only 288 SP PD Guide...
Страница 310: ...This soft copy for use by IBM employees only 290 SP PD Guide...
Страница 316: ...IBML This soft copy for use by IBM employees only Printed in U S A SG24 4778 00...