This soft copy for use by IBM employees only.
/usr/lpp/ssp/bin/hrd
The inittab entry:
hr:2:once:/usr/bin/startsrc -g hr >/dev/null 2>/dev/console
If it has died or did not start on boot, run:
# startsrc -g hr
The host_responds daemon (like the SDR daemon) only runs on the Control
Workstation. Remember that if the problematic node is running AIX Version
3.2.5, then check for the
ccst process instead of the hbd process.
If all the daemons are running, it is still worth recycling them all just in case any
of the daemons are no longer functioning as they should.
If there is no connectivity across
en0, then test the connectivity across the other
network interfaces to the problem node. Test to see if a console can be opened
across the serial link. If there is connectivity across other interfaces, and the
node is up and working, then resolve the network issues with the
en0 interface.
Here are some possible scenarios:
•
An application or process is generating a large amount of traffic across
en0
so that the heartbeat times out
−
The internal Ethernet should ideally be dedicated to
SP-related traffic for
this reason.
•
The interface has gone down or been corrupted
−
Check with the
ifconfig
command and remove and rebuild the interface
with the
rmdev
and
mkdev
commands if necessary.
If there is no connectivity across any of the interfaces, then check to see what
the status is of any users that are already logged in. If their sessions are
hung
(that is, if there is no response to typing anything on the keyboard), then check
the
LED display for the node using the
spmon
GUI.
If the node has crashed, then there will be either an
888 LED displayed, or an
associated crash code (such as
0c9, for example). In this case, reboot the node
after ensuring that it has finished taking a system dump and contact IBM support
for assistance in analyzing the dump data.
If the node shows no sign of having crashed but there is absolutely no response
at all to any commands, then force a system dump (according to the instructions
given in Chapter 8, “Producing a System Dump” on page 201), reboot the node,
and contact IBM support.
If the node responds to commands but does so in a fashion that is slower than
normal, then it may be possible to analyze the performance at this time to
identify what might be causing this problem.
5.5.2 The Heartbeat after System Partitioning
During the
apply of the partitions, multiple heartbeat and host_responds
daemons get created and started. The
spapply_config
command uses the
information in the
Syspar_map object class to identify which subsystems to build.
Each partition has one heartbeat and one host_responds daemon. Unlike the
SDR daemons, it is not possible to identify which daemon services which
154
SP PD Guide
Содержание RS/6000 SP
Страница 2: ......
Страница 14: ...This soft copy for use by IBM employees only xii SP PD Guide...
Страница 16: ...This soft copy for use by IBM employees only xiv SP PD Guide...
Страница 106: ...This soft copy for use by IBM employees only 86 SP PD Guide...
Страница 178: ...This soft copy for use by IBM employees only 158 SP PD Guide...
Страница 214: ...This soft copy for use by IBM employees only 194 SP PD Guide...
Страница 248: ...This soft copy for use by IBM employees only 228 SP PD Guide...
Страница 250: ...This soft copy for use by IBM employees only Figure 102 setup_authent Script Flow Chart 2 7 230 SP PD Guide...
Страница 252: ...This soft copy for use by IBM employees only Figure 104 setup_authent Script Flow Chart 4 7 232 SP PD Guide...
Страница 254: ...This soft copy for use by IBM employees only Figure 106 setup_authent Script Flow Chart 6 7 234 SP PD Guide...
Страница 258: ...This soft copy for use by IBM employees only Figure 110 install_cw Script Flow Chart 3 3 238 SP PD Guide...
Страница 260: ...This soft copy for use by IBM employees only Figure 112 setup_server Script Flow Chart 2 23 240 SP PD Guide...
Страница 262: ...This soft copy for use by IBM employees only Figure 114 setup_server Script Flow Chart 4 23 242 SP PD Guide...
Страница 264: ...This soft copy for use by IBM employees only Figure 116 setup_server Script Flow Chart 6 23 244 SP PD Guide...
Страница 266: ...This soft copy for use by IBM employees only Figure 118 setup_server Script Flow Chart 8 23 246 SP PD Guide...
Страница 268: ...This soft copy for use by IBM employees only Figure 120 setup_server Script Flow Chart 10 23 248 SP PD Guide...
Страница 270: ...This soft copy for use by IBM employees only Figure 122 setup_server Script Flow Chart 12 23 250 SP PD Guide...
Страница 272: ...This soft copy for use by IBM employees only Figure 124 setup_server Script Flow Chart 14 23 252 SP PD Guide...
Страница 274: ...This soft copy for use by IBM employees only Figure 126 setup_server Script Flow Chart 16 23 254 SP PD Guide...
Страница 276: ...This soft copy for use by IBM employees only Figure 128 setup_server Script Flow Chart 18 23 256 SP PD Guide...
Страница 278: ...This soft copy for use by IBM employees only Figure 130 setup_server Script Flow Chart 20 23 258 SP PD Guide...
Страница 280: ...This soft copy for use by IBM employees only Figure 132 setup_server Script Flow Chart 22 23 260 SP PD Guide...
Страница 284: ...This soft copy for use by IBM employees only Figure 136 rc switch Script Flow Chart 3 8 264 SP PD Guide...
Страница 286: ...This soft copy for use by IBM employees only Figure 138 rc switch Script Flow Chart 5 8 266 SP PD Guide...
Страница 288: ...This soft copy for use by IBM employees only Figure 140 rc switch Script Flow Chart 7 8 268 SP PD Guide...
Страница 290: ...This soft copy for use by IBM employees only 270 SP PD Guide...
Страница 292: ...This soft copy for use by IBM employees only 272 SP PD Guide...
Страница 300: ...This soft copy for use by IBM employees only 280 SP PD Guide...
Страница 304: ...This soft copy for use by IBM employees only 284 SP PD Guide...
Страница 308: ...This soft copy for use by IBM employees only 288 SP PD Guide...
Страница 310: ...This soft copy for use by IBM employees only 290 SP PD Guide...
Страница 316: ...IBML This soft copy for use by IBM employees only Printed in U S A SG24 4778 00...