This soft copy for use by IBM employees only.
From the command line:
To add, remove, or show error notification objects in parallel on the SP system,
enter:
penotify -f show
Useful options with the
penotify
command are:
-a
Executes on all nodes in the system partition.
-c
Specifies the error class.
-f
Specifies the function: show, add, remove.
-m
method
Specifies the notification method.
-n
name
Specifies the name of the notification object.
-w
hosts
Run the command on a file or a list of hosts names separated by
commas or blanks.
-P
This option will cause the object to persist after the system is
restarted.
Note that you must be defined as a Kerberos principal in the /etc/logmgt.acl file
to run this command.
To view all notification object on the nodes sp21n1, sp21n2, and sp21n3, enter:
penotify -w sp21n1,sp21n2,sp21n3 -f show
To remove the notification object named HDISK0_ERR on all nodes, enter:
penotify -a -f remove -n HDISK0_ERR
The AIX Error Notification facility can notify you when an SP error occurs. The
error notification will perform an ODM method defined by the administrator when
a particular error occurs or a particular process fails.
The following classifications of errors should have notifications defined by the
administrator. Many of these messages will not occur often, so these notification
objects should be defined even for large SP systems.
1. PPS AIX Error Label that end in _EM
The _EM suffix signifies an emergency error and is usually used to tell the
administrator some information that would be needed to reboot a node. You
can find these messages by issuing the command:
errpt -t | grep
″_
EM
″
2. Any AIX Error Log entries that have an Error Type of PEND
The error type PEND signifies an impending loss of availability and action
will soon be required by the administrator.
3. Any AIX Error Log entries for the boot device of the node
The boot device of the node usually is a resource of hdisk0, but the name
may vary if the installation has been customized.
4. The AIX Error Label EPOW_SUS
The EPOW_SUS error log entry is generated prior to a system power down
when an unexpected loss of electrical power is encountered.
Chapter 6. E r r o r Logging
179
Содержание RS/6000 SP
Страница 2: ......
Страница 14: ...This soft copy for use by IBM employees only xii SP PD Guide...
Страница 16: ...This soft copy for use by IBM employees only xiv SP PD Guide...
Страница 106: ...This soft copy for use by IBM employees only 86 SP PD Guide...
Страница 178: ...This soft copy for use by IBM employees only 158 SP PD Guide...
Страница 214: ...This soft copy for use by IBM employees only 194 SP PD Guide...
Страница 248: ...This soft copy for use by IBM employees only 228 SP PD Guide...
Страница 250: ...This soft copy for use by IBM employees only Figure 102 setup_authent Script Flow Chart 2 7 230 SP PD Guide...
Страница 252: ...This soft copy for use by IBM employees only Figure 104 setup_authent Script Flow Chart 4 7 232 SP PD Guide...
Страница 254: ...This soft copy for use by IBM employees only Figure 106 setup_authent Script Flow Chart 6 7 234 SP PD Guide...
Страница 258: ...This soft copy for use by IBM employees only Figure 110 install_cw Script Flow Chart 3 3 238 SP PD Guide...
Страница 260: ...This soft copy for use by IBM employees only Figure 112 setup_server Script Flow Chart 2 23 240 SP PD Guide...
Страница 262: ...This soft copy for use by IBM employees only Figure 114 setup_server Script Flow Chart 4 23 242 SP PD Guide...
Страница 264: ...This soft copy for use by IBM employees only Figure 116 setup_server Script Flow Chart 6 23 244 SP PD Guide...
Страница 266: ...This soft copy for use by IBM employees only Figure 118 setup_server Script Flow Chart 8 23 246 SP PD Guide...
Страница 268: ...This soft copy for use by IBM employees only Figure 120 setup_server Script Flow Chart 10 23 248 SP PD Guide...
Страница 270: ...This soft copy for use by IBM employees only Figure 122 setup_server Script Flow Chart 12 23 250 SP PD Guide...
Страница 272: ...This soft copy for use by IBM employees only Figure 124 setup_server Script Flow Chart 14 23 252 SP PD Guide...
Страница 274: ...This soft copy for use by IBM employees only Figure 126 setup_server Script Flow Chart 16 23 254 SP PD Guide...
Страница 276: ...This soft copy for use by IBM employees only Figure 128 setup_server Script Flow Chart 18 23 256 SP PD Guide...
Страница 278: ...This soft copy for use by IBM employees only Figure 130 setup_server Script Flow Chart 20 23 258 SP PD Guide...
Страница 280: ...This soft copy for use by IBM employees only Figure 132 setup_server Script Flow Chart 22 23 260 SP PD Guide...
Страница 284: ...This soft copy for use by IBM employees only Figure 136 rc switch Script Flow Chart 3 8 264 SP PD Guide...
Страница 286: ...This soft copy for use by IBM employees only Figure 138 rc switch Script Flow Chart 5 8 266 SP PD Guide...
Страница 288: ...This soft copy for use by IBM employees only Figure 140 rc switch Script Flow Chart 7 8 268 SP PD Guide...
Страница 290: ...This soft copy for use by IBM employees only 270 SP PD Guide...
Страница 292: ...This soft copy for use by IBM employees only 272 SP PD Guide...
Страница 300: ...This soft copy for use by IBM employees only 280 SP PD Guide...
Страница 304: ...This soft copy for use by IBM employees only 284 SP PD Guide...
Страница 308: ...This soft copy for use by IBM employees only 288 SP PD Guide...
Страница 310: ...This soft copy for use by IBM employees only 290 SP PD Guide...
Страница 316: ...IBML This soft copy for use by IBM employees only Printed in U S A SG24 4778 00...