007
– Press Reset and wait for the system green (OK) and yellow LEDs to start
blinking or the system green (OK) to come on and the yellow LED to be blinking.
– Press the service terminal break key sequence and press Enter.
– Press Ctrl-c at the service terminal.
The terminal displays the
>
prompt.
– Enter uc at the prompt.
The 2216 displays the hardware configuration. The first line shows the autobaud
speed and the configured service port baud rate, if they are different.
Are different autobaud and configured speeds displayed?
Yes No
008
– Go to Step 010.
009
– Set the terminal to the configured console baud rate displayed.
– Press the service terminal break key sequence and press Enter.
This action causes the 2216 to autobaud.
– Enter Ctrl-c.
The
>
prompt should be displayed. If the console baud rate is satisfactory, you can
reboot the 2216 and the terminal will work. If the console baud rate is
unsatisfactory and you want to change the rate:
1. Enter bc at the
>
prompt and select an IBD boot module.
2. Wait for the
Config (only)
>
prompt to be displayed.
3. Enter set baudrate 0 at the
Config (only)
>
prompt.
4. Set the terminal to the desired baud rate.
5. Press the terminal break key sequence and press Enter to force the 2216 to
autobaud to the new terminal speed.
Note: When using a terminal emulator, you may have to stop and restart the
emulator when switching speeds for the emulator to display correctly.
– Continue at Step 010.
010
The terminal should now operate correctly and the new terminal speed has been
saved.
(Step 010 continues)
Chapter 1. Problem Determination
1-11
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 8: ...vi 2216 Maintenance Manual ...
Страница 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Страница 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Страница 60: ...3 6 2216 Maintenance Manual ...
Страница 84: ...4 24 2216 Maintenance Manual ...
Страница 104: ...A 2 2216 Maintenance Manual ...
Страница 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Страница 110: ...B 6 2216 Maintenance Manual ...
Страница 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Страница 138: ...F 12 2216 Maintenance Manual ...
Страница 150: ...UWAGA Całkowicie wypełnione urządzenie IBM 2216 waży około 43 1 kg H 6 2216 Maintenance Manual ...
Страница 164: ......
Страница 167: ......