Slots and Adapters
There are two large slots, designated
A and B, on the IBM 2216. Slot A is unused.
Slot
B is occupied by the system card. In addition, there are eight adapter slots,
designated
1 through 8.
¹
No more than
six of any combination of Token-Ring (FC 2280) and Ethernet
(FC 2281) adapters can be installed.
¹
If a combination of
six 2280 and 2281 adapters is to be installed, no other
adapters will be installed.
¹
If a combination of
five 2280 and 2281 adapters is to be installed, then two
additional adapters can also be installed.
¹
The IBM 2216 supports a maximum of:
–
Four ESCON adapters (FC 2287)
–
Two ATM adapters (FC 2284 or FC 2293)
–
Four ISDN adapters (FC 2283 or FC 2292)
Note: You can configure a 2216 with as many high speed adapters
(FDDI FC 2286, 10/100-Mbps Ethernet FC 2288, and HSSI FC 2289) as
desired; however, you may not be able to achieve full media throughput
concurrently on all the adapters. When planning for installation, review
system performance expectations with an IBM representative.
Any adapter can be installed in any of the eight adapter slots with the following
restrictions:
1
If the 2-port Token-Ring (FC 2280) or 2-port Ethernet (FC 2281) adapter is
plugged into slot 3 and active, then slot 4 cannot be used.
2
If the 2-port Token-Ring (FC 2280) or 2-port Ethernet (FC 2281) is plugged
into slot 4 and active, then slot 3 cannot be used.
3
If the 2-port Token-Ring (FC 2280) or 2-port Ethernet (FC 2281) adapter is
plugged into slot 7 and active, then slot 8 cannot be used.
4
If the 2-port Token-Ring (FC 2280) or 2-port Ethernet (FC 2281) adapter is
plugged into slot 8 and active, then slot 7 cannot be used.
E-2
2216 Maintenance Manual
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 8: ...vi 2216 Maintenance Manual ...
Страница 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Страница 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Страница 60: ...3 6 2216 Maintenance Manual ...
Страница 84: ...4 24 2216 Maintenance Manual ...
Страница 104: ...A 2 2216 Maintenance Manual ...
Страница 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Страница 110: ...B 6 2216 Maintenance Manual ...
Страница 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Страница 138: ...F 12 2216 Maintenance Manual ...
Страница 150: ...UWAGA Całkowicie wypełnione urządzenie IBM 2216 waży około 43 1 kg H 6 2216 Maintenance Manual ...
Страница 164: ......
Страница 167: ......