Power Supply Status
LEDs
Meaning
Yellow
(Overcurrent)
On - There is an overcurrent condition with the
−
48 V to one or
more of the adapters (slots 1–8) or the
+
12 V to the fan tray.
Green DC
On -
+
5 V,
+
12 V, and
−
48 V are OK.
Green AC
On - AC source voltage is present and within tolerance.
System Card Status
LEDs
Meaning
PCMCIA 1 or
PCMCIA 2
(Yellow)
On - PCMCIA device has a fault, is not installed, or is not seated
correctly.
Off - Device passed self-tests
OK (Green)
On - Card hardware is operating normally.
Blinking - Loading from hard file
OK (Yellow)
On - Card hardware has a fault.
Fault Hard Drive
(Yellow)
On - Hard drive has failed.
Adapter Card Status
LEDs
Meaning
OK (Green)
On - Adapter is operational.
OK (Yellow)
On - Adapter has a fault.
Wrong slot
(Yellow)
On - Adapter is in the wrong slot.
The wrong slot LED is ON only when an adapter that is plugged into
the 2216 violates the plugging rules described in Appendix E,
“Adapter Plugging Defaults” on page E-1.
Green port
1
On - Port is operating normally (enabled and configured).
Off - Port is not configured or is disabled.
For the ESCON adapter:
Blinking - The optical power measurement test is running.
Yellow port
1
On - One or more ports has a hardware fault.
Blinking - One or more ports has a port I/O or network failure. Use
the Maintenance Analysis Procedures (MAPs) to isolate.
Off - No problem detected.
Important Phone Numbers
Contact Name
Telephone Number
System Administrator:
Service Representative:
1
The port LEDs of the multiport WAN adapters (FC 2282, FC 2291, and FC 2292) reflect the status of one or more of the ports.
Chapter 1. Problem Determination
1-3
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 8: ...vi 2216 Maintenance Manual ...
Страница 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Страница 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Страница 60: ...3 6 2216 Maintenance Manual ...
Страница 84: ...4 24 2216 Maintenance Manual ...
Страница 104: ...A 2 2216 Maintenance Manual ...
Страница 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Страница 110: ...B 6 2216 Maintenance Manual ...
Страница 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Страница 138: ...F 12 2216 Maintenance Manual ...
Страница 150: ...UWAGA Całkowicie wypełnione urządzenie IBM 2216 waży około 43 1 kg H 6 2216 Maintenance Manual ...
Страница 164: ......
Страница 167: ......