Device List
"For more information on each device select from the following list:
Device
Location
Status
Token Ring
Slot 1
Multi-Port
Adapter
ENABLED
< 1. Token Ring> Slot 1
Port 1
Net # 0
ENABLED
Token Ring
Slot 1
Port 2
NOT CONFIGURED
< 2. ATM MMF >
Slot 2
Port 1
Net # 1
DISABLED
< 3. ESCON >
Slot 3
Single Port
Net # 2
ENABLED
< 4. ESCON >
Slot 4
Single Port
--
NOT CONFIGURED
Some of the devices are note currently available for testing.
This can occur
when a test is not available for the device or when the device must be
configured in order to be tested,
Select (1-4 or D=Down B=Back
R=Refresh h=Help):
Figure
5-2. Sample of Device List Panel Showing Interfaces
The Device List is the starting point for running a test. It also provides a
check to determine if all of the installed devices are being recognized by the
2216.
The Device List includes a summary status for each device. The devices
that are testable or that have additional status available can be selected.
Selecting a device will then display the Device Status and Control page for
that device.
The Status displayed for a device may have the following values:
ENABLED
Device is enabled for normal operation. For
multi-port devices this means that at least one port is
enabled.
ENABLE PENDING
Waiting for completion of Enable request.
Special
Device is in a special state that is explained on the
Device Status and Control Page.
DISABLED
Device is Disabled. Diagnostic testing can now be
performed. For multi-port Devices this means that
all ports are disabled.
DISABLE PENDING
Waiting for completion of Disable request.
MESSAGE
Select the device to view and respond to the
message.
TESTING
The device is being tested.
NOT CONFIGURED
The device is not configured for normal operation.
MIS CONFIGURED
The configuration does not match the physical
device.
HARDWARE ERROR A Hardware Error has been detected which prevents
further use of the device.
Chapter 5. Using Operational Diagnostics
5-3
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 8: ...vi 2216 Maintenance Manual ...
Страница 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Страница 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Страница 60: ...3 6 2216 Maintenance Manual ...
Страница 84: ...4 24 2216 Maintenance Manual ...
Страница 104: ...A 2 2216 Maintenance Manual ...
Страница 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Страница 110: ...B 6 2216 Maintenance Manual ...
Страница 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Страница 138: ...F 12 2216 Maintenance Manual ...
Страница 150: ...UWAGA Całkowicie wypełnione urządzenie IBM 2216 waży około 43 1 kg H 6 2216 Maintenance Manual ...
Страница 164: ......