Testing the Adapters
Running Diagnostics on the Adapter
The following is a sample sequence with sample screens for running the
diagnostics. The selections that you see during your test may be different.
Before running the test, disable the adapter (see “Suspend Traffic on an Adapter
Port” on page F-7).
1
At the OPCON (*) prompt, type diags and press Enter.
2
The Diagnostic Menu (see Figure 5-1 on page 5-2) appears. To make a
selection type in the number of your choice and press Enter.
3
Type 1 and press Enter to access the Device List Page.
4
Select a device to test (for example, type 4 for ESCON) to test the ESCON
channel adapter in slot 4.
5
Select Run Interactive Test. The Test Options menu appears:
@
Screen 1 of 1
Test Options
LIC 287 - ESCON Channel Adapter, Slot 4
Operational Status
Diagnostic Status
Fault Status
Network Connection
NOT CONFIGURED
MESSAGE
UNKNOWN
UNKNOWN
Do not remove this device while testing.
Select one of the following test options:
* < 1. Run all tests excluding external wrap test >
* < 2. Run all tests including external wrap test >
Individual tests:
* < 3. PCI BUS >
* < 4. PROCESSOR >
* < 5. MEMORY >
* < 6. MEMORY PROT >
* < 7. TIMER >
* < 8. AIB >
* < 9. WRAP PLUG >
* <10. OPTICAL POWER >
* <11. LIGHT RECEPTION >
Select (1-11 or
B=Back R=Refresh H=Help ):2
Chapter 5. Using Operational Diagnostics
5-9
Содержание Nways 2216
Страница 1: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 2: ......
Страница 3: ...2216 Nways Multiaccess Connector ÉÂÔ Service and Maintenance Manual SY27 0350 02 ...
Страница 8: ...vi 2216 Maintenance Manual ...
Страница 10: ...Common Tasks and the IBM 2216 Library viii 2216 Maintenance Manual ...
Страница 45: ...6 Remove the adapter from its location Chapter 2 Removal and Replacement Procedures 2 15 ...
Страница 60: ...3 6 2216 Maintenance Manual ...
Страница 84: ...4 24 2216 Maintenance Manual ...
Страница 104: ...A 2 2216 Maintenance Manual ...
Страница 106: ...Assembly 1 Final Assembly 2216 Model 400 B 2 2216 Maintenance Manual ...
Страница 110: ...B 6 2216 Maintenance Manual ...
Страница 114: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 Power Cord Plugs by Country C 4 2216 Maintenance Manual ...
Страница 138: ...F 12 2216 Maintenance Manual ...
Страница 150: ...UWAGA Całkowicie wypełnione urządzenie IBM 2216 waży około 43 1 kg H 6 2216 Maintenance Manual ...
Страница 164: ......
Страница 167: ......