Chapter 6. Solving problems
115
AFT group for primary adapter in slot
nnn
already exists.
Explanation:
An attempt was made to rebind an adapter already in an AFT
group.
Action:
Check the AFT slot numbers for existing AFT teams. If the problem
persists, contact your network supplier.
Error locating device control table
(DCT) addresses in internal table.
Make sure that you have loaded LAN
drivers after loading AFT.NLM.
Explanation:
The bind command was entered prior to loading the device
driver. The device driver must be loaded after loading AFT.NLM, but before any
bind command can be issued.
Action:
Load the driver for the supported adapter and try loading the AFT
module again. If the problem persists, contact your network supplier.
Insufficient number of arguments
specified.
Explanation:
The appropriate or expected number of parameters was not
entered in a command.
Action:
Check the parameters required for the given command. If the problem
persists, contact your network supplier.
Duplicate slot numbers detected.
Explanation:
An attempt has been made to bind the same slot number more
than once.
Action:
Check the slot numbers entered during the bind. Adapter slot numbers
must be valid and unique. If the problem persists, contact your network
supplier.
’
xxx
’ is not supported for AFT team.
Explanation:
A bind command has been issued for adapters not supported by
AFT.NLM.
Action:
Make sure that you attempt to bind only adapters supported by
AFT.NLM.
Primary and Secondary adapters do
not match. AFT group is not created.
Explanation:
A bind command was entered for an adapter team that is a
combination of system and client adapters. An AFT team must be a grouping of
the same classification of adapter.
Action:
Verify that all the adapters bound in a team are of the same
classification.
Requested number of Secondary
cards are not found.
Explanation:
The number of adapters specified in the bind command could not
be located.
Action:
Verify the numbers and slot locations of the adapters to be bound. If
the problem persists, contact your network supplier.
Failed to create AFT group. Make
sure that the drivers for supported
adapters are loaded, primary adapter
is bound to protocols, and secondary
adapter is not bound to any protocols.
Explanation:
Binding of protocol failed. Protocol is either not bound to any
adapter or is bound to more than one adapter in the group.
Action:
Ensure that the protocol is bound to only one adapter in an AFT team.
Error identifying slot numbers for the
specified board names.
Explanation:
The mapping between the board name entered and the slot
number for an adapter could not be established.
Action:
Check the board name for the adapter before issuing the bind
command. If the problem persists, contact your network supplier.
Can’t unbind specified slot from AFT
group. Make sure that the slot you
specified is for the primary adapter in
an AFT group.
Explanation:
The number entered in the unbind command was not the primary
adapter in an AFT group.
Action:
Reissue the unbind command and specify the slot number for the
primary adapter.
Table 19. NetWare driver messages for the Ethernet controller.
Message
Description