Chapter 6. Solving problems
99
166
System
Management
Failed
ISMP Self Test Result failed test:
x
(where
x
identifies part of the
subsystem experiencing problems,
x
= [ROM, RAM, flash])
Flash (or reflash) latest
firmware levels. Call for service.
I2C Bus Error(s)
If an system management
adapter is installed, reconnect
I2C cable between system
management adapter and
system board. Call for service.
I2C cable is disconnected.
Reconnect I2C cable between
system management adapter
and system board. Call for
service if the problem persists.
BIOS indicates ASM is unreachable.
Ensure ASM adapter is properly
seated in its supported slot.
Ensure the optional system
management adapter (IBM
Remote Supervisor Adapter), is
seated in PCI Slot 1 (J44).
Unable to communicate with ASM
adapter. It may be busy.
Communication with the ASM adapter
has failed.
Rerun the test. Call for service if
the problem persists.
ASM BIST indicate failed tests.
Unable to restart ASM adapter.
Disconnect all external server
and option power cords from
server, wait 30 seconds,
reconnect, and retry. Call for
service if the problem persists.
175
System thermal
Failed
Fan #
n
(where
n
is the number of the failing
fan)
Note:
The fan LED on the diagnostic
LED panel will be lit.
Replace the indicated fan.
Temperature sensed on processor
board is out of range
If one of the fan LEDs on the
diagnostic LED panel is on,
replace the indicated fan. If the
problem persists, call for
service.
180
Status display
Failed
Diagnostic LED panel
Call for service.
Operator information panel
LED on hot-swap SCSI backplane
LED on system board
One or more fan LEDs are faulty.
Replace the faulty fan.
201
System memory Failed
DIMMs in location DIMM
n
(where
n
is the number of the socket
that contains the failing DIMM)
1.
Reseat the failing DIMM.
2.
If the problem remains,
replace the DIMM.
If the problem persists, call
for service.
Test setup error: Corrupt BIOS in
ROM
If your server does not have the
latest level BIOS installed,
update the BIOS to the latest
level.
If the problem persists, call for
service.
Test setup error: Corrupt DMI BIOS,
information in BIOS is not as expected
Code
Function
Result
Text message
Action