84
IBM xSeries 342: User’s Reference
1-2-4
RAM refresh verification has failed.
Reseat the memory modules or
install a memory module. If the
problem persists, call for service.
1-3-1
First 64 Kb RAM test has failed.
1-3-2
First 64 Kb RAM parity test has failed.
3-3-1
A memory size mismatch has occurred.
3-3-2
Screen initialization has failed. I2C bus has failed.
Turn off the server, unplug the
server cord, wait 20 seconds
until the power-on LED stops
blinking. Reconnect the ac
power cord and then start the
server. If the problem persists,
call for service.
3-3-3
No memory has been detected in the system.
Attention:
In some memory configurations, the 3-3-3
beep code might sound during POST, followed by a
blank screen. If this occurs, you must restart the server
three times to force the system BIOS to reset the
memory connector or bank of connectors from Disabled
to Enabled.
Reseat the memory modules or
install a memory module. If the
problem persists, call for service.
4-4-4
The I2C cable is attached and, the optional system
management adapter is not installed in PCI slot 1 or not
functioning correctly.
1.
Turn off the server.
2.
Verify that the cable is
installed correctly. If it is not,
disconnect the cable and
reconnect it correctly.
3.
Verify that the optional
system-management
adapter is installed in PCI
slot 1. If it is not, remove the
system-management
adapter from the slot and
reinstall it in PCI slot 1.
4.
Verify that the optional
system-management
adapter is functioning
correctly. If it is not, remove
it and call for service.
If the problem persists, call for
service.
Table 12. POST beep codes.