88
IBM xSeries 342: User’s Reference
301 303
An error occurred during the keyboard and keyboard controller test. These error messages also
might be accompanied by continuous beeping.
Action:
Ensure that:
1.
Nothing is resting on the keyboard and pressing a key.
2.
No key is stuck.
3.
The keyboard cable is connected correctly to the keyboard and to the correct
connector on the server.
Running the diagnostic tests can isolate the server component that failed, but you must have
your system serviced. If the error message remains, call for service.
Note:
If you just connected a new mouse or other pointing device, turn off the server and
disconnect that device. Wait at least 5 seconds; then, turn on the server. If the error
message goes away, replace the device.
602
Invalid diskette boot record
Action:
1.
Replace the diskette.
2.
If the problem persists, make sure that the diskette drive cables are correctly and
securely connected.
3.
If the problem remains, replace the diskette drive.
If the problem remains, call for service.
604
An error occurred during a diskette drive test.
Action:
1.
Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2.
Run the diagnostic tests. If the diagnostic tests fail, call for service.
662
A diskette drive configuration error occurred.
Action:
If you removed a diskette drive, make sure that the diskette drive setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem remains, call for service.
11
xx
An error occurred during the system-board serial port test.
Action:
If you have a modem, serial printer, or other serial device attached to your server,
verify that the serial cable is connected correctly. If it is, use the following procedure:
1.
Turn off the server.
2.
Disconnect the serial cable from the serial port.
3.
Wait five seconds; then, turn on the server.
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing
information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1.
Make sure the IRQ and I/O port assignments needed by the serial port are
available.
2.
If all interrupts are being used by adapters, you might need to remove an adapter
to make an interrupt available to the serial port, or force other adapters to share
an interrupt.
POST message
Description
Table 13. POST error messages.