Software/Hardware Mismatch Problems
If a failure appears to be the result of a defective FRU, but
the diagnostic tests run error-free, there might be a
software and hardware mismatch. These problems might
be intermittent, and they are usually difficult to diagnose.
If you are experiencing this type of problem, and the
operating system is of the “direct driver” variety, which
bypasses the BIOS interface, such as:
AIX
Netware
SCO UNIX
Some “windowing” interfaces
Other Unix-based software
the most-likely cause of the problem is a mismatch
between the software and the hardware.
The following information is provided to help you resolve
these problems:
Software Can Be Sensitive to the Hardware
Direct-driver software is sensitive to variations in hardware
design. The resulting incompatibilities are usually
addressed with a revision (sometimes referred to as a
patch), to the direct-driver software. Make certain the
software is current and that all known revisions are
installed. The IBM on-line bulletin board (sometimes
referred to as PCPROD), and other software tools sources,
such as Novell Netware, should be referenced by the
software support personnel for any revisions provided by
the appropriate software vendor.
The most-likely cause of these types of problems, when
direct-driver software is involved, is the failure to obtain the
latest revisions from the software vendor.
Software Installation
It is very important to follow the vendor's installation
procedures. The software should not be migrated from
another system, unless the installation instructions indicate
that migration is supported (especially from a different
model in the product line).
Important
Migrating adapters from slower systems to faster
systems might cause problems. This is due to
device-specific, system-specific, or time-dependent
software code, that controls these devices.
Related Service Information
133
Содержание 8639 - PC Server 325
Страница 97: ...Drawer Model Rails Drives 92 PC Server HMM...
Страница 102: ...Operator Panel and Cable Note Loosen do not remove screw Screw PC Server 325 Type 8639 97...
Страница 108: ...System Board Note Note A black square indicates pin 1 PC Server 325 Type 8639 103...
Страница 120: ...Parts Listings 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 17 18 20 19 PC Server 325 Type 8639 115...
Страница 121: ...21 23 24 25 22 26 27 28 29 30 116 PC Server HMM...
Страница 129: ...124 PC Server HMM...
Страница 145: ...IBM Part Number 84H3049 Printed in U S A S84H 3 49...