Specifications (PC Server 325 - Type
8639)
Size
With pedestal:
–
Depth: 473 mm (18.6 in.)
569 mm (22.6 in.) with cable cover
–
Height: 455 mm (17.9 in.)
–
Width: 315 mm (12.4 in.)
Without pedestal:
–
Depth: 473 mm (18.6 in.)
569 mm (22.6 in.) with cable cover
–
Height: 425 mm (16.7 in.)
–
Width: 195 mm (7.7 in.)
Drawer model:
–
Depth: 465 mm (18.3 in.)
–
Height: 216 mm (8.5 in.)
–
Width: 482 mm (19.0 in.)
Weight
Typical server as shipped: 17.0 kg (37.5 lb)
Environment
Air temperature:
–
Server on: 10° to 35° C
(50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)
–
Server on: 10° to 32° C
(50° to 90° F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
–
Server off: 10° to 43° C
(50° to 110° F)
Maximum Altitude: 2133 m (7000 ft.)
Humidity:
–
Server on: 8% to 80%
–
Server off: 8% to 80%
Maximum altitude: 2133 m (7000 ft)
Electrical Input
Sine-wave input (50 to 60 Hz) is required
Input voltage:
–
Low range:
-
Minimum:
90 V ac
-
Maximum: 137 V ac
–
High range:
-
Minimum: 180 V ac
-
Maximum: 265 V ac
–
Input kilovolt-amperes (kVA) approximately:
-
Minimum configuration as shipped: 0.08 kVA
-
Maximum configuration: 0.52 kVA
Total Power Available for Drives
Nominal Operating Current allowed:
–
+5 V dc line: 5.3 A
–
+12 V dc line: 5.0 A
Heat Output
Approximate heat output in British Thermal Units (BTU)
per hour:
–
Minimum configuration: 350 BTU (102 watts)
–
Maximum configuration: 860 BTU (251 watts)
86
PC Server HMM
Содержание 8639 - PC Server 325
Страница 97: ...Drawer Model Rails Drives 92 PC Server HMM...
Страница 102: ...Operator Panel and Cable Note Loosen do not remove screw Screw PC Server 325 Type 8639 97...
Страница 108: ...System Board Note Note A black square indicates pin 1 PC Server 325 Type 8639 103...
Страница 120: ...Parts Listings 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 17 18 20 19 PC Server 325 Type 8639 115...
Страница 121: ...21 23 24 25 22 26 27 28 29 30 116 PC Server HMM...
Страница 129: ...124 PC Server HMM...
Страница 145: ...IBM Part Number 84H3049 Printed in U S A S84H 3 49...