Error Codes
In the following error codes,
X can be any number or letter.
Error Code/Symptom
FRU/Action
E100, E101
(Invalid EISA configuration)
1. Run EISA
Configuration
2. Failing EISA adapter
3. Real-Time Clock with
Battery
4. System Board
E10X
(Invalid EISA configuration
for Slot X)
1. Run EISA
Configuration
2. Failing EISA adapter in
slot X
101, 102
(System and microprocessor
error)
1. System Board
2. Microprocessor Board
106
(System and microprocessor
error)
1. System Board
2. Microprocessor Board
111
(I/O channel check error)
1. Failing EISA/ISA
Adapter
2. Memory DIMM
3. System Board
114
(Adapter read-only memory
error)
1. Failing Adapter
2. Run Diagnostics
129
(Internal Cache error)
1. Optional
Microprocessor
(if installed)
2. Microprocessor
3. Microprocessor Board
151
(Real time clock error)
1. Run Diagnostics
2. Real-Time Clock with
Battery
3. System Board
162
(Device Configuration Error)
1. Run
Configuration/Setup;
then, run the EISA
Configuration Utility
2. Failing Device
3. Real-Time Clock with
Battery
4. System Board
163
(Real-Time Clock error)
1. Run
Configuration/Setup
2. Real-Time Clock with
Battery
3. System Board
164
(Memory configuration
changed)
1. Run
Configuration/Setup
2. DIMM
3. Microprocessor Board
PC Server 325 - Type 8639
111
Содержание 8639 - PC Server 325
Страница 97: ...Drawer Model Rails Drives 92 PC Server HMM...
Страница 102: ...Operator Panel and Cable Note Loosen do not remove screw Screw PC Server 325 Type 8639 97...
Страница 108: ...System Board Note Note A black square indicates pin 1 PC Server 325 Type 8639 103...
Страница 120: ...Parts Listings 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 17 18 20 19 PC Server 325 Type 8639 115...
Страница 121: ...21 23 24 25 22 26 27 28 29 30 116 PC Server HMM...
Страница 129: ...124 PC Server HMM...
Страница 145: ...IBM Part Number 84H3049 Printed in U S A S84H 3 49...