USING HYDRO-VIEW SERIAL PORTS
HYDRO-VIEW USER GUIDE
D0022
REV 1.06
77
Code
Mnemonic
Description
02
BAD_DATA
The data field contained data which was out of range for
the specific request.
03
BAD_LENGTH
The frame length was incorrect for the request. This
would normally mean that you have supplied either too
little or too much data.
Additional acknowledge codes may be added in future versions.
Reply frame format
Issued by slave stations.
The station number has the top bit set as described in
Basic Frame Format
above.
The request field is returned unaltered.
The data field is a series of single bytes (two hex digits) code according to the request
frame being processed.
Request frame types (‘command set’)
The different types of request which a slave will respond to are given below in terms of the
request code (hexadecimal), request data field and reply frame description.
Read Moisture - request code 01
This will return the current moisture values from the slave together with some status flags.
Request data
Format
Description
Material
number
HH
Two hex digits (one byte) representing the material number
to use in the range allowed by the Hydro-View (currently
decimal 1-10).
If this field is set to 00, then the material number in the
slave will not be changed.
The slave will not allow its material number to be changed
unless it is configured appropriately.
Reply data
Format
Description
Now value
HHHH
Four hex digits (two bytes, LSB first) representing the
instantaneous (NOW) moisture % in the slave.
The data transmitted is in 0.01% units.
Average value
HHHH
Four hex digits (two bytes, LSB first) representing the batch
AVERAGE moisture % in the slave.
The data transmitted is in 0.01% units.
Control flags
HH
Two hex digits (one byte) representing some status flags as
follows...
Bit
Description
0-3
Represent the state of the batch average/hold
function. This is coded numerically as follows...
0 - Hold state
1 - Timing (Average/hold delay)
2 - Averaging
3 - Low material level
4-F - currently undefined.
4
Set-point 1 status
5
Set-point 2 status
6
Material low level (if configured)
7
Alarm output on.
Содержание Hydro-View HV02
Страница 20: ...20 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 30: ...MATERIAL IN USE 30 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 42: ...SUGGESTED WORKING VALUES 42 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 48: ......
Страница 53: ...GROUPING CHANNELS HYDRO VIEW USER GUIDE D0022 REV 1 06 53 Figure 17 Four bin grouped system ...
Страница 54: ...EXAMPLE A FOUR BIN GROUPED SYSTEM USING RS485 54 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 69: ...INSTALLATION HYDRO VIEW USER GUIDE D0022 REV 1 06 69 Notes ...
Страница 70: ......
Страница 80: ...ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 80 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 82: ...82 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...