SUGGESTED WORKING VALUES
40
HYDRO-VIEW USER GUIDE
D0022
REV 1.06
Suggested working values
The example configurations given in this section should be used as a guide in developing
your own systems. However, the applications of the Hydro-View are not limited to these
applications. The examples show the minimum configurations required and in general do
not show variations in the use of interfacing techniques, each of which is described
elsewhere.
The following tables give recommended working values for the three examples described
in
Applications of Hydro-View with Hydronix moisture sensors
(p10). These should be
treated as starting points, although in practice very little tuning should be required. These
values will need to be adjusted to suit changes to interfacing arrangements which may
have been employed.
Sensor set-up
Parameter name
Batch weigher
Batch mixer
Continuous
process
Type 1
1
1
Samples 5
75
1
100
2
A/H delay
0.5
0
0
Sync delay
0.00
0.00
0.00
+dV Coarse
1.00
0.02
0.02
-dV Coarse
1.00
0.05
0.02
+dV Fine
0.10
0.01
0.02
-dV Fine
0.10
0.02
0.02
Minimum volts
0.5V
0.5
0.5
Maximum volts
12.0V
12.0
12.0
Trend step (s)
1.0
1.0
1.0
Trend lower %
0.00
0.00
0.00
Trend upper %
20.00
20.00
20.00
Alarm Lo %
0.00
0.00
0.00
Alarm Hi %
20.00
20.00
20.00
Output set-up
Parameter name
Batch weigher
Batch mixer
Continuous
process
Minimum %
0.00
0.00
0.00
Maximum %
20.00
20.00
20.00
Calibrate %
0.00
0.00
0.00
Variable AVERAGE
NOW
NOW
Sensor calibration
Parameter name
Batch weigher
Batch mixer
Continuous
process
Unscaled i/p 1
4.15
4.15
4.15
Moisture % 1
0.00
0.00
0.00
Unscaled i/p 2
28.40
28.40
28.40
Moisture % 2
11.00
11.00
11.00
SSD %
0.00
3
0.00 0.00
1
Depends on rotational speed of mixer. This is three rotations at 2.5 seconds.
2
Depends on time constants in feedback control system. This will give a response time of around 10 seconds.
3
Normally set to reflect the absorption properties of material in ready-mix applications.
Содержание Hydro-View HV02
Страница 20: ...20 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 30: ...MATERIAL IN USE 30 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 42: ...SUGGESTED WORKING VALUES 42 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 48: ......
Страница 53: ...GROUPING CHANNELS HYDRO VIEW USER GUIDE D0022 REV 1 06 53 Figure 17 Four bin grouped system ...
Страница 54: ...EXAMPLE A FOUR BIN GROUPED SYSTEM USING RS485 54 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 69: ...INSTALLATION HYDRO VIEW USER GUIDE D0022 REV 1 06 69 Notes ...
Страница 70: ......
Страница 80: ...ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 80 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 82: ...82 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...