INTRODUCTION
HYDRO-VIEW USER GUIDE
D0022
REV 1.06
11
A batch weighing system
A typical example of a batch weighing system involving a moisture measurement point (in
this case a Hydro-Probe) at the output of the storage bin is shown in Figure 1.
The Hydro-View is interfaced as follows...
⇒
Feed a signal to a digital input on the Hydro-View indicating when the gate is open.
This signal can be derived either from a limit switch on the gate or from an auxiliary
contact on the
Open gate
output in the batch control system, whichever is most
convenient. Configure this input as an Average/Hold input (see
Input 1 / Input 2
use
on page 36).
⇒
Connect the Hydro-Probe sensor to the Hydro-View in the standard way.
⇒
Connect the analogue output to the batch computer and set the output variable to
AVERAGE. The output range should be set according to the working moisture
range of the material; for most concrete batch applications, the default values of 0
and 20% are appropriate.
Refer to
Installation
later in this document for wiring details.
You may be tempted to short-cut this approach in some of the ways described below - if
you do this, you are unlikely to achieve satisfactory results and Hydronix cannot provide
technical support under these circumstances.
Recommendations for best performance
A
LWAYS
make use of the average/hold facility. Even if your batch computer is computing
the average moisture value in the batch, you will still need to display the average unscaled
•
Figure 1 - Batch weighing example
Содержание Hydro-View HV02
Страница 20: ...20 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 30: ...MATERIAL IN USE 30 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 42: ...SUGGESTED WORKING VALUES 42 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 48: ......
Страница 53: ...GROUPING CHANNELS HYDRO VIEW USER GUIDE D0022 REV 1 06 53 Figure 17 Four bin grouped system ...
Страница 54: ...EXAMPLE A FOUR BIN GROUPED SYSTEM USING RS485 54 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 69: ...INSTALLATION HYDRO VIEW USER GUIDE D0022 REV 1 06 69 Notes ...
Страница 70: ......
Страница 80: ...ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 80 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 82: ...82 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...