![Hydronix Hydro-View HV02 Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/hydronix/hydro-view-hv02/hydro-view-hv02_user-manual_2192338073.webp)
USING HYDRO-VIEW SERIAL PORTS
HYDRO-VIEW USER GUIDE
D0022
REV 1.06
73
•
Figure 33 - RS485 module circuit board
The RS485 module also includes RS485 line bias resistors to bias an un-driven line to a
known condition. ONE module only in a system should have these enabled by inserting
jumpers J1 and J2 - normally this would be done on the unit configured as a MASTER
station.
The RS485 module is supplied with J1, J2 and J3 installed by default.
Data log mode
The Hydro-View provides a continuous stream of data output on the relevant port which
may be captured by an external device.
This data stream is in ASCII format and contains the NOW and AVERAGE moisture
values according to the programmed data log rate.
The data format used is as follows...
<STX>NNN.NN,AAA.AA<CRLF>
where...
<STX>
is the ASCII start of text character (hex 02).
NNN.NN
is the NOW moisture value in the range -99.99
to 99.99%.
AAA.AA
is the AVERAGE moisture value in the range -
99.99 to 99.99%.
<CRLF>
is the ASCII carriage return - line feed
combination (hex 0D, hex 0A).
The data rate/format used is 9600 baud, 8 data bits, no parity, 1 stop bit. This cannot be
altered.
The data logging format changes when the unit is configured as a Master on the other
serial port. The data stream is again in ASCII format and contains the GROUP moisture
values updated according to the programmed data log rate.
The data format used is as follows...
<STX>MMM.MM,NNN.NN,AAA.AA<CRLF>
where...
<STX>
is the ASCII start of text character (hex 02).
MMM.MM
is the group M1 value in the ranger -99.99 to 99.99%.
NNN.NN
is the group M2 value in the range -99.99 to 99.99%.
J1-J3 termination jumpers
Содержание Hydro-View HV02
Страница 20: ...20 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 30: ...MATERIAL IN USE 30 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 42: ...SUGGESTED WORKING VALUES 42 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 48: ......
Страница 53: ...GROUPING CHANNELS HYDRO VIEW USER GUIDE D0022 REV 1 06 53 Figure 17 Four bin grouped system ...
Страница 54: ...EXAMPLE A FOUR BIN GROUPED SYSTEM USING RS485 54 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 69: ...INSTALLATION HYDRO VIEW USER GUIDE D0022 REV 1 06 69 Notes ...
Страница 70: ......
Страница 80: ...ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 80 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 82: ...82 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...