FIELD CONNECTIONS
56
HYDRO-VIEW USER GUIDE
D0022
REV 1.06
Adjusting the Hydro-View mains operating voltage
The mains input voltage for the Hydro-View is selected
internally as follows…
1. Remove the 7 screws securing the lid to the case.
2. Remove the lid to reveal the mains transformer and
power supply assembly which is mounted on the
inside of the lid.
3. Move the BROWN wire to select the appropriate
mains voltage as indicated in Figure 19 opposite.
4. Refit the lid and screws.
5. Indicate the new operating voltage on the rear panel
using the labels supplied.
Field connections
All field connections (except mains and RS232 serial port) are made via plug-in screw
terminal blocks located on the rear panel of the instrument.
You should refer also to the wiring labels fitted to the lid of the Hydro-View.
The terminals (numbered 1 through 21) are allocated as follows…
Terminal
group
Group function
Terminal
Description
1 - 5
Moisture sensor
connections
1
+15V sensor power
2
0V sensor power return
3
-15V sensor power
4
0-10V sensor input +
5
0-10V sensor input -
6,7
Analogue output
6
0-10V or 4-20mA analogue output
7
Analogue output return
8-12
RS485 serial port
8
Data A
9 Data
B
10
11
12
RS485 0V (for test purposes only)
13-17
Digital inputs
13
+Vdc Input excitation supply
14
Digital input 1
15
Digital input 2
16
Digital input common
17
0Vdc Input excitation supply return
18-21
Relay outputs
18
Relay common
19 Alarm
20
Set-point 1 or material select output 1
21
Set-point 2 or material select output 2
•
Figure 19 - Hydro-View mains
transformer
Содержание Hydro-View HV02
Страница 20: ...20 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 30: ...MATERIAL IN USE 30 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 42: ...SUGGESTED WORKING VALUES 42 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 48: ......
Страница 53: ...GROUPING CHANNELS HYDRO VIEW USER GUIDE D0022 REV 1 06 53 Figure 17 Four bin grouped system ...
Страница 54: ...EXAMPLE A FOUR BIN GROUPED SYSTEM USING RS485 54 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 69: ...INSTALLATION HYDRO VIEW USER GUIDE D0022 REV 1 06 69 Notes ...
Страница 70: ......
Страница 80: ...ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 80 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...
Страница 82: ...82 HYDRO VIEW USER GUIDE D0022 REV 1 06 Notes ...