132
OPERATION
Start-up
HBR204-MU-6-eng.doc
OPERATION AND MAINTENANCE INSTRUCTION MANUAL
THIS DOCUMENT IS THE PROPERTY OF HÜETTE BOHRTECHNIK GMBH - TOTAL OR PARTIAL REPRODUCTION IS PROHIBITED
4.5. Start-up
4.5.1. Checks before starting the diesel engine
Duties of the operator:
1)
Carefully perform visual inspection around the machine to check for problems and
anomalies:
-
fluid leaks;
-
missing or damaged parts;
-
loose mechanical or hydraulic connections;
-
anomalies on safety protections.
2)
Check the following levels:
-
hydraulic oil level;
-
engine oil level;
-
engine coolant level.
If the following anomalies are present, the diesel
engine must not be started:
-
Low level hydraulic oil.
-
Working controls activated.
3)
Check automatic return to the neutral position of
the levers (radio remote control);
4)
Check automatic return to the neutral position of
the selectors (radio remote control);
5)
Place the levers with stop in the neutral position (radio remote control);
6)
Put the selectors in position 0 (neutral) (radio remote control);
7)
Check that all emergency buttons have been released (S110, S105)
2.6