background image

Dimensions:

B124 Tone Control

1.260

.510

.400

CCW W CW

1
2
3
4

TONE

B124rH

SOLDERING:

If you don’t have connector cables, or prefer to solder to the control, 

solder pads are provided. The diagram to the right shows the pads for 

soldering.

.965

.650

SOLID SHAFT

SPLIT SHAFT

      

General Operation

The B124 Passive Tone control is included with original EMG Pickups and Pickup Systems.  There are two versions, 25K Ohm for Active EMG’s 

and 500K Ohm for EMG-HZ Passive Pickups. The 25K Ohm control has a black PC Board, the 500K has a green PC Board, both are Audio Taper. 

The wiring configuration is the same for both 25K and 500K Controls. The tone capacitor is small and is mounted on the pot side of the PC Board. 

There are 4 header pins, (2 pairs of signal and ground) the two pairs are identical so either can be used for tone control with the second pair 

for in/out. Examples are shown in the included diagrams. The B124 features plug-in compatibility with all EMG Pickup Systems by using .100 

(2.54mm) standard pin spacing. You can solder to the control by using the 2 solder pads on the PC Board if connectors are not available, 1 of 

the solder pads is for input and the other pad is for ground, see below.

0230-0162B

INSTALLATION INFORMATION

 

EMG MODEL: 

B124 TONE CONTROL

(ACTIVE PICKUP INPUT 25K OHM, BLACK PC BOARD)
(PASSIVE PICKUP INPUT 500K OHM, GREEN PC BOARD) 

 © 2009 Copyright EMG INC. All Rights Reserved.

PO BOX 4394 
SANTA ROSA, CA
95402  USA

P (707) 525-9941
F (707) 575-7046
EMGPICKUPS.COM

Schematic Diagram:

B124 Tone Control

GROUND

The EMG coax cables for wiring the guitar are a 2-pin pair, 

The signal or “Hot” wire is White, the Ground (Shield) wire is Black.  

8mm Dia.

P.75

C1

104

A25K

CCW

W

CW

1
2
3
4

IN/OUT

GND

IN/OUT

GND

 *HZ VALUES

A500K*

473*

CW (CLOCKWISE)
INPUT

SCHEMATIC NOTES:

The Schematic diagram above shows how the B124 Tone control is configured.

Pins 1 and 2 are the input to the CW (Clockwise) terminal of the control. 

Pins 3 and 4 are a duplicate of the CW (Clockwise) terminal of the control.

Pins 2 and 4 go directly to ground.

 

Отзывы: