l
If the command outputs do not contain the preceding information, the network-side device
has accepted the call. Go to step 6.
Step 6
Check that the protocol status of the data channel is Up.
Run the
display isdn active-channel
command to check the activated data channel.
<Huawei>
display isdn active-channel
Serial1/0/0:15
-------------------------------------------------------------------------------
Channel Call Call Calling Calling Called
Called
Info Property Type Number Subaddress Number
Subaddress
-------------------------------------------------------------------------------
B26 Digital Out 88888204 - 88888206 -
Run the
display interface
serial 1/0/0:15
command to check the data channel corresponding to
the call. If the protocol status is Line protocol current state : Up, the protocol status of the data
channel is Up. Go to step 7.
If the protocol status is Line protocol current state : DOWN, the protocol status of the data
channel is Down. Rectify the fault according to
5.7.1 Protocol Status of a PPP Interface Is
Step 7
Collect the following information and contact Huawei technical support personnel.
l
Results of the preceding troubleshooting procedure
l
Configuration files, log files, and alarm files of the AR2200-S
----End
Relevant Alarms and Logs
Relevant Alarms
None.
Relevant Logs
None.
5.4.2 Failed to Receive Calls
Common Causes
This fault is commonly caused by one of the following:
l
A link is not set up.
l
The AR2200-S does not receive the call.
l
The AR rejects the call because the interaction packet type is incorrect.
l
The network-side device rejects the call because the interaction packet type is incorrect.
Huawei AR2200-S Series Enterprise Routers
Troubleshooting
5 WAN
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
103